Fault finding: what to check before you ring.

Breakdown work is charged at £99 + VAT per hour with a one-hour minimum, so the five minutes you spend on this page is genuinely worth something — sometimes it fixes the problem, and when it does not, it tells James what to bring.

First, the one thing that is not a plumbing call

If you can smell gas, ring the National Gas Emergency Service on 0800 111 999 immediately. Turn the gas off at the meter if you can safely reach it, open windows and doors, do not touch any electrical switch or doorbell, do not use your phone inside the building, and get everyone out. The same applies if a carbon monoxide alarm sounds: get out into fresh air first and ring from outside. Put the repair second — JET Heating can deal with that afterwards.

No heating or hot water

Nothing is coming on at all

  • Is the programmer actually calling for heat? Timers lose their schedule after a power cut, and smart thermostats lose it after a flat battery or a router change.
  • Is the room thermostat set above the current room temperature, and does it have working batteries?
  • Is there power to the boiler — a switched fuse spur near it, or a tripped breaker in the consumer unit?
  • Is the system pressure gauge reading somewhere around 1 to 1.5 bar when the system is cold? Below half a bar, most boilers refuse to fire.
  • If you are on oil: is there oil in the tank? It is the first question for a reason, and a sight gauge that has stuck at a quarter full is very common.

In short — Those five account for a large share of "dead boiler" calls. If all of them check out, it is a fault rather than a setting, and it needs an engineer.

Locked out

The boiler shows a fault code and will not restart

  • Write the code down exactly as it appears, along with the make and model from the data badge — that alone often tells James what part to bring.
  • Reset once, and once only. If it locks out again, something is genuinely wrong and repeated resets can make it worse.
  • In cold weather, look at the condensate pipe — a white plastic pipe leaving the boiler and usually running outside. A frozen condensate is the classic winter lock-out, and gently warming the outside section can revive it.
  • Listen for the pump running and feel whether the pipes get warm at all before it cuts out. Heating and then stopping points somewhere different from never firing.

In short — Send the fault code and a photo of the data badge on WhatsApp before ringing — it saves time on the phone and sometimes saves a visit.

Losing pressure

You keep topping the system up

  • Note how fast it falls: a bar a week, or a bar overnight. The rate narrows the cause down more than anything else.
  • Check the outside wall near the boiler for a small pipe dripping when the heating runs — that is the pressure relief valve discharging, and it is a repair rather than a top-up.
  • Look under radiator valves and at any visible joints for the tell-tale greenish or white crust that says a slow weep.
  • Count how often you have refilled it. Every refill adds fresh oxygenated water, which is what turns a small leak into sludged radiators a few years later.

In short — Do not keep topping it up indefinitely and hope. A failed expansion vessel is an hour's work; a buried leak needs finding before it finds your ceiling.

Cold radiators

Hot at the top, cold at the bottom — or cold all over

  • Cold at the bottom and warm at the top is almost always sludge, not air. Bleeding will not fix it.
  • Cold at the top and warm at the bottom is air, and bleeding it usually will fix it — check the system pressure afterwards.
  • One radiator cold while the rest are hot: check both valves are open, including the lockshield under the plastic cap, and that a thermostatic head has not seized shut. Tapping a stuck TRV pin gently sometimes frees it.
  • All the upstairs radiators cold: suspect the pump, a zone valve, or a system that needs balancing rather than the boiler.

In short — Sludge is a system problem, so the fix is a clean and a magnetic filter rather than a new radiator — otherwise the same thing happens again.

Oil specific

The oil boiler will not light, or lights and smells

  • Check the tank level properly, and check for water in the bottom of the tank if it has not been drained in years.
  • Look at the fire valve — a fusible-link safety valve on the oil line near the boiler. If it has tripped, it needs an engineer, not resetting and forgetting.
  • Listen: motor running with no ignition usually means nozzle, electrodes or pump. No motor at all points at power, the control box or a lock-out reset.
  • Soot smells or black staining around the case mean it is burning badly. Turn it off and ring rather than running it "until someone can come".

In short — Oil work needs OFTEC registration — JET Heating holds it, which is the reason a lot of the villages off the mains gas grid ring here.

What to send when you ring

  • · A photo of the boiler's data badge — make, model and GC number.
  • · A photo of the display, with the fault code showing.
  • · A photo of the pressure gauge, cold if possible.
  • · One line on what changed: “since the power cut”, “since we had the floor up”, “it has been getting worse all winter”.

WhatsApp them to 07391 701168 and you will get a straight answer about whether it needs a visit, what it is likely to be, and what it is likely to cost.